Product Details
Sinergy Has Reimagined Solar Inverters with the New Bilz Series with first-in-segment features
- But What’s So Special? A brand new “Solar Maximizer”
- No other Inverter has an innovative feature to bring the best out of your Solar Panels.
- No other inverter in its class can run entirely on Solar and give you practically a 0 Electricity bill.
- This feature allows users to use maximum Solar Power from the Solar PV panels and reduce dependency on Grid Power.
- It will not only reduce the electricity bill but also help save the environment. – Introducing All new Solar Bliz Series- A Modern Pure Sine Wave Solar Inverter / UPS range, endowed with first-in-segment features
- The pure Sine Wave output is Clean, Regulated, Completely Stable, Distortion Free and Safe for running the most sophisticated and sensitive modern appliances.
- Based on Advanced / Next Gen DSP technology, Bliz ensures the highest Safety and efficiency in the class
MODEL: Sinergy Bliz 1250
System Rating (VA/W): 900VA
INPUT PARAMETERS
Nominal Input Battery Voltage: 12 V
Main Input Voltage Range (UPS Mode): 180 VAC – 265 VAC ± 5 VAC
Main Input Voltage Range (Normal Mode): 100 VAC – 280 VAC ± 15 VAC
BATTERY CHARGING
Grid Charging Current: 6A, 9A, 12A & 15A (Selectable)
MODES
UPS/NORMAL: Via Switch
Charging Mode: 6A, 10A, 14A & 18A
Battery Mode: b0 , b1 , b2 and b3 Via Switch
OUTPUT PARAMETERS
Waveform Type: SINE WAVE
Output Voltage Regulation: 200 VAC ± 10%
Output Frequency: 50 Hz ± 0.5 Hz
Overload Protection: Provided at >100% with Auto Reset
Low Battery Protection: Provided with Auto Reset
Short Circuit Protection: Provided at >300% with Manual Reset
Over Temperature Protection: Provided at >85 Degree ℃
CHANGE OVER TIME
In UPS Mode: <14 milliseconds
In Normal Mode: <50 milliseconds
BATTERY PARAMETER (PER BATTERY)
Boost Voltage: Mode b0 / TT : 14.6 VDC ± 0.2 VDC, Mode b1 / SMF : 14.4 VDC ± 0.2 VDC
Float Voltage: Mode b0 / TT : 13.8 VDC ± 0.2 VDC, Mode b1 / SMF : 13.6 VDC ± 0.2 VDC
Low Battery Warning: Mode b0 / TT : 10.6 VDC ± 0.2 VDC, Mode b1 / SMF : 11.1 VDC ± 0.2 VDC
Low Battery Cut: Mode b0 / TT : 10.4 VDC ± 0.2 VDC, Mode b1 / SMF : 10.8 VDC ± 0.2 VDC
ENVIRONMENT
Forced Cooling: Through Cooling FAN
Humidity: 0-90% Non Condensing
Operating & Storage Temperature: 0-45℃
DISPLAY PARAMETERS
Display Type: LCD + LED DISPLAY (GRAPHICAL REPRESENTATION)
Parameters: Mains voltage, Charging current, Battery Charging / Charged show in battery symbol, Battery Voltage, Load voltage , Load current DC, Load percentage, UPS mode, battery mode, charging mode, Low Battery, Overload, Short Circuit, Over Temperature, Mains MCB Trip
LED INDICATION
Mains LED: Continuous ON when mains available
Switch Press LED: Blink when any switch pressed
Fault LED: ON when system in Fault condition