Genus Heiwa-i 2050 Sine Wave UPS Inverter for Home
- 4 Types of Battery Selection mode: B0: TT – Tall Tubular B1: SMF – Sealed Maintenance Free B2: FT – Flat Tubular B3: Battery Revival Mode
- 4 Types Charging Current Selection Switch (6A, 9A, 12A, 15A)
- UPS/NOR Mode Selection Switch
- Battery Wire type – Copper
- Mains Lead with Top and Reset-able AC Fuse
- Suitable for 0.5 HP Motor Run
Product Details
The Genus Heiwa-i is, the most affordable Home UPS Inverter designed to be aesthetically pleasing, compact to fit any corner and not to detract from the décor of your home or office, this machine from Genus keeps you away from frequent power cuts.
Genus Heiwa-i is an all-in-one system that eliminates the need for a separate power backup system for computers and other sophisticated applications.
It’s compatible with all battery types from a normal lead-acid battery to a heavy-duty tubular battery. The user-selectable boost charging mode charges the battery faster, leading to significant power savings and lower electricity bills.
Power ON/OFF switch(Touch Feel, UPS/NOS mode selection switch (Touch Feel),3 Types battery selection switch with battery REVIVAL option (Touch Feel), 4 Types charging current selection switch(Touch Feel Battery Revival Mode “B3 )
MODEL: Genus Heiwa-i 2050 Sine Wave UPS Inverter for Home
System Rating (VA/W): 2000VA
INPUT PARAMETERS
Nominal Input Battery Voltage: 12 V
Main Input Voltage Range (UPS Mode): 180 VAC – 265 VAC ± 5 VAC
Main Input Voltage Range (Normal Mode): 100 VAC – 280 VAC ± 15 VAC
BATTERY CHARGING
Grid Charging Current: NC : 11A; HC : 15A
MODES
UPS/NORMAL: Via Switch
Charging Mode: 6A, 9A, 12A & 15A (Select-able)
Battery Mode: b0 , b1 , b2 and b3 Via Switch
OUTPUT PARAMETERS
Waveform Type: PURE SINE WAVE
Output Voltage Regulation: 200 VAC ± 10%
Output Frequency: 50 Hz ± 0.5 Hz
Overload Protection: Provided at >100% with Auto Reset
Low Battery Protection: Provided with Auto Reset
Short Circuit Protection: Provided at >300% with Manual Reset
Over Temperature Protection: Provided at >85 Degree ℃
CHANGE OVER TIME
In UPS Mode: <15 milliseconds
In Normal Mode: <50 milliseconds
BATTERY PARAMETER (PER BATTERY)
Boost Voltage:
Mode b0 / TT : 14.6 VDC ± 0.2 VDC
Mode b1 / SMF : 14.4 VDC ± 0.2 VDC
Mode b2 / FT : 14.4 VDC ± 0.2 VDC
Mode b3 / Battery Revival : 15.6 VDC ± 0.2 VDC (depends upon battery)
Float Voltage:
Mode b0 / TT : 13.8 VDC ± 0.2 VDC
Mode b1 / SMF : 13.6 VDC ± 0.2 VDC
Mode b2 / FT : 13.7 VDC ± 0.2 VDC
Mode b3 / Battery Revival : 13.8 VDC ± 0.2 VDC
Low Battery Warning:
Mode b0 / TT : 10.6 VDC ± 0.2 VDC
Mode b1 / SMF : 11.1 VDC ± 0.2 VDC
Mode b2 / FT : 10.8 VDC ± 0.2 VDC
Low Battery Cut:
Mode b0 / TT : 10.4 VDC ± 0.2 VDC
Mode b1 / SMF : 10.8 VDC ± 0.2 VDC
Mode b2 / FT : 10.6 VDC ± 0.2 VDC
ENVIRONMENT
Forced Cooling: Through Cooling FAN
Humidity: 0-90% Non Condensing
Operating & Storage Temperature: 0-45℃
DISPLAY PARAMETERS
Display Type: LCD + LED DISPLAY (GRAPHICAL REPRESENTATION)
Parameters: Mains voltage, Charging current, Battery Charging / Charged show in battery symbol, Battery Voltage, Load voltage , Load current DC, Load percentage, UPS mode, battery mode, charging mode, Low Battery, Over-load, Short Circuit, Over Temperature, Mains MCB Trip
LED INDICATION
Mains LED: Continuous ON when mains available
Switch Press LED: Blink when any switch pressed
Fault LED: ON when system in Fault condition
Note : Specifications and models subject to change without prior notice