Product Details
A Powerful and Superior Alternative to Gensets and Other Static Inverters.
Bliz Static inverter from Genus allows computers, sensitive pieces of equipment, air conditioners and other high load capacity appliances to function safely during power cuts. Pure Sine wave output power is cleaner than the power supplied from the grid, thereby ensuring the total safety of home and office appliances.
No Maintenance Cost, No Movable Items: Unlike diesel generators, Genus Heiwa does not have movable parts to maintain, reducing the maintenance and increasing the service life of the UPS. Inbuilt Smart Overload and Short Circuit Protection keep the load safe even in the worst power conditions.
MODEL: Sinergy – Bliz – 3500 – 48 V
System Rating (VA/W): 3500VA
INPUT PARAMETERS
Nominal Input Battery Voltage: 48 V
Main Input Voltage Range (UPS Mode): 180 VAC – 265 VAC ± 5 VAC
Main Input Voltage Range (Normal Mode): 100 VAC – 280 VAC ± 15 VAC
BATTERY CHARGING
Grid Charging Current: 6A, 9A, 12A & 15A (Selectable)
MODES
UPS/NORMAL: Via Switch
Charging Mode: 6A, 10A, 14A & 18A
Battery Mode: b0 , b1 , b2 and b3 Via Switch
OUTPUT PARAMETERS
Waveform Type: SINE WAVE
Output Voltage Regulation: 200 VAC ± 10%
Output Frequency: 50 Hz ± 0.5 Hz
Overload Protection: Provided at >100% with Auto Reset
Low Battery Protection: Provided with Auto Reset
Short Circuit Protection: Provided at >300% with Manual Reset
Over Temperature Protection: Provided at >85 Degree ℃
CHANGE OVER TIME
In UPS Mode: <14 milliseconds
In Normal Mode: <50 milliseconds
BATTERY PARAMETER (PER BATTERY)
Boost Voltage: Mode b0 / TT : 14.6 VDC ± 0.2 VDC, Mode b1 / SMF : 14.4 VDC ± 0.2 VDC
Float Voltage: Mode b0 / TT : 13.8 VDC ± 0.2 VDC, Mode b1 / SMF : 13.6 VDC ± 0.2 VDC
Low Battery Warning: Mode b0 / TT : 10.6 VDC ± 0.2 VDC, Mode b1 / SMF : 11.1 VDC ± 0.2 VDC
Low Battery Cut: Mode b0 / TT : 10.4 VDC ± 0.2 VDC, Mode b1 / SMF : 10.8 VDC ± 0.2 VDC
ENVIRONMENT
Forced Cooling: Through Cooling FAN
Humidity: 0-90% Non Condensing
Operating & Storage Temperature: 0-45℃
DISPLAY PARAMETERS
Display Type: LCD + LED DISPLAY (GRAPHICAL REPRESENTATION)
Parameters: Mains voltage, Charging current, Battery Charging / Charged show in battery symbol, Battery Voltage, Load voltage , Load current DC, Load percentage, UPS mode, battery mode, charging mode, Low Battery, Overload, Short Circuit, Over Temperature, Mains MCB Trip
LED INDICATION
Mains LED: Continuous ON when mains available
Switch Press LED: Blink when any switch pressed
Fault LED: ON when system in Fault condition
Product Features
Four Modes Battery Selection
Four Modes High Charging Selection
Genus ASIC Technology
Dual Display