Genus Heiwa 48V 6500 Pure Sinewave Heavy Duty Static Home & Commercial UPS
- Energy Saver Mode consumes less power in a no-load condition
- Highly Robust & Reliable User Friendly LCD Display
- User Selectable HC (High Charging) / NC (Normal Charging) Switch Status
- Advanced Genus ASIC Charging Technology
- Smart Over Load and Short Circuit Protection
- Modern Pure Sine Wave Home Inverter UPS with LCD
Product Details
Genus Statica is based on the most advanced DSP technology.
It is a much superior alternative to commercial UPS. The output power is the pure sine wave purer than the power supplied from the grid, ensuring the total safety of home and office appliances.
Genus STATICA also possesses various modern features which provide quiet, hassle-free performance for years and substantially longer battery life. Genus Statica keeps you away from frequent power cuts.
Genus Statica is an all-in-one system that eliminates the need for a separate power backup system for computers and other sophisticated applications. It’s compatible with all battery types, from a standard lead-acid battery to a heavy-duty tubular battery.
MODEL: Genus Heiwa 48V 6500 Pure Sinewave Heavy Duty Static Home & Commercial UPS
System Rating (VA/W): 5000VA
INPUT PARAMETERS
Nominal Input Battery Voltage: 48 V
Main Input Voltage Range (UPS Mode): 180 VAC – 265 VAC ± 5 VAC
Main Input Voltage Range (Normal Mode): 100 VAC – 280 VAC ± 15 VAC
BATTERY CHARGING
Grid Charging Current: 6A, 10A, 14A & 18A (Selectable)
MODES
UPS/NORMAL: Via Switch
Charging Mode: 6A, 10A, 14A & 18A
Battery Mode: b0 , b1 , b2 and b3 Via Switch
OUTPUT PARAMETERS
Waveform Type: SINE WAVE
Output Voltage Regulation: 200 VAC ± 10%
Output Frequency: 50 Hz ± 0.5 Hz
Overload Protection: Provided at >100% with Auto Reset
Low Battery Protection: Provided with Auto Reset
Short Circuit Protection: Provided at >300% with Manual Reset
Over Temperature Protection: Provided at >85 Degree ℃
CHANGE OVER TIME
In UPS Mode: <14 milliseconds
In Normal Mode: <50 milliseconds
BATTERY PARAMETER (PER BATTERY)
Boost Voltage: Mode b0 : 14.1 VDC ± 0.2 VDC Mode, b1 : 14.4 VDC ± 0.2 VDC Mode, b2 : 14.4 VDC ± 0.2 VDC Mode b3 : 14.6 VDC ± 0.2 VDC
Float Voltage: Mode b0 : 13.8 VDC ± 0.2 VDC Mode, b1 : 13.6 VDC ± 0.2 VDC Mode, b2 : 13.6 VDC ± 0.2 VDC Mode b3 : 13.8 VDC ± 0.2 VDC
Low Battery Warning: Mode b0 : 11.0 VDC ± 0.2 VDC Mode, b1 : 11.0 VDC ± 0.2 VDC Mode, b2 : 10.7 VDC ± 0.2 VDC Mode b3 : 10.6 VDC ± 0.2 VDC
Low Battery Cut: Mode b0 : 10.8VDC ± 0.2 VDC Mode, b1 : 10.8 VDC ± 0.2 VDC Mode, b2 : 10.5 VDC ± 0.2 VDC Mode b3 : 10.4 VDC ± 0.2 VDC
ENVIRONMENT
Forced Cooling: Through Cooling FAN
Humidity: 0-90% Non Condensing
Operating & Storage Temperature: 0-45℃
DISPLAY PARAMETERS
Display Type: LCD + LED DISPLAY (GRAPHICAL REPRESENTATION)
Parameters: Mains voltage, Charging current, Battery Charging / Charged show in battery symbol, Battery Voltage, Load voltage , Load current DC, Load percentage, UPS mode, battery mode, charging mode, Low Battery, Overload, Short Circuit, Over Temperature, Mains MCB Trip
LED INDICATION
Mains LED: Continuous ON when mains available
Switch Press LED: Blink when any switch pressed
System on backup LED: Blinking when system on backup and mains unavailable
Fault LED: ON when system in Fault condition
Product Features
Four Modes Battery Selection
Four Modes High Charging Selection
Genus ASIC Technology
Dual Display